b486678290
Library -Artifacts
49 lines
3.5 KiB
C#
49 lines
3.5 KiB
C#
////REVIEW: could have a monitor path where if there's multiple state monitors on the same control with
|
|
//// the same listener, the monitor is notified only once but made aware of the multiple triggers
|
|
|
|
namespace UnityEngine.InputSystem.LowLevel
|
|
{
|
|
/// <summary>
|
|
/// Interface used to monitor input state changes.
|
|
/// </summary>
|
|
/// <remarks>
|
|
/// Use <see cref="InputState.AddChangeMonitor(InputControl,IInputStateChangeMonitor,long,uint)"/> to install a state change monitor receiving state change
|
|
/// callbacks for a specific control.
|
|
/// </remarks>
|
|
/// <seealso cref="InputState.AddChangeMonitor(InputControl,IInputStateChangeMonitor,long,uint)"/>
|
|
public interface IInputStateChangeMonitor
|
|
{
|
|
////REVIEW: For v2, consider changing the signature of this to put the "was consumed" signal *outside* the eventPtr
|
|
/// <summary>
|
|
/// Called when the state monitored by a state change monitor has been modified.
|
|
/// </summary>
|
|
/// <param name="control">Control that is being monitored by the state change monitor and that had its state
|
|
/// memory changed.</param>
|
|
/// <param name="time">Time on the <see cref="InputEvent.time"/> timeline at which the control state change was received.</param>
|
|
/// <param name="eventPtr">If the state change was initiated by a state event (either a <see cref="StateEvent"/>
|
|
/// or <see cref="DeltaStateEvent"/>), this is the pointer to that event. Otherwise it is pointer that is still
|
|
/// <see cref="InputEventPtr.valid"/>, but refers a "dummy" event that is not a <see cref="StateEvent"/> or <see cref="DeltaStateEvent"/>.</param>
|
|
/// <param name="monitorIndex">Index of the monitor as passed to <see cref="InputState.AddChangeMonitor(InputControl,IInputStateChangeMonitor,long,uint)"/>.
|
|
/// </param>
|
|
/// <remarks>
|
|
/// To signal that the state change has been processed by the monitor and that no other pending notifications on the
|
|
/// same monitor instance should be sent, set the <see cref="InputEventPtr.handled"/> flag to <c>true</c> on <paramref name="eventPtr"/>.
|
|
/// Note, however, that aside from only silencing change monitors on the same <see cref="IInputStateChangeMonitor"/> instance,
|
|
/// it also only silences change monitors with the same <c>groupIndex</c> value as supplied to
|
|
/// <see cref="InputState.AddChangeMonitor(InputControl,IInputStateChangeMonitor,long,uint)"/>.
|
|
/// </remarks>
|
|
void NotifyControlStateChanged(InputControl control, double time, InputEventPtr eventPtr, long monitorIndex);
|
|
|
|
/// <summary>
|
|
/// Called when a timeout set on a state change monitor has expired.
|
|
/// </summary>
|
|
/// <param name="control">Control on which the timeout expired.</param>
|
|
/// <param name="time">Input time at which the timer expired. This is the time at which an <see cref="InputSystem.Update"/> is being
|
|
/// run whose <see cref="InputState.currentTime"/> is past the time of expiration.</param>
|
|
/// <param name="monitorIndex">Index of the monitor as given to <see cref="InputState.AddChangeMonitor(InputControl,IInputStateChangeMonitor,long,uint)"/>.</param>
|
|
/// <param name="timerIndex">Index of the timer as given to <see cref="InputState.AddChangeMonitorTimeout"/>.</param>
|
|
/// <seealso cref="InputState.AddChangeMonitorTimeout"/>
|
|
void NotifyTimerExpired(InputControl control, double time, long monitorIndex, int timerIndex);
|
|
}
|
|
}
|